Basic Command Class

Description

Value

Function

Energy Saving Mode

0

Sets swing parameter to 3 and sets differential parameter to 6

Comfort Mode

1-99, 255

Sets swing parameter to 1 and sets differential parameter to 3

Configuration Controls

Display Units

Parameter Number:

  • 1

Size (bytes):

  • 1

Range:

  • 0: C
  • 1: F
  • Default: 1

HVAC Setting

Parameter Number:

  • 2

Size (bytes):

  • 1

Range:

  • 0: 1 Stage Conventional
  • 1: 2 Stage Conventional
  • 2: Heat Pump w/ O-Wire
  • 3: Heat Pump w/ B-Wire
  • 4: Heat Pump w/ O-Wire & aux heating
  • 5: Heat Pump w/ B-Wire & aux heating
  • Default: 1

ECO Mode

Parameter Number:

  • 3

Size (bytes):

  • 1

Range:

  • 0: Off
  • 1: On
  • Default: 0

Thermostat Default Settings

Parameter Number:

  • 4

Size (bytes):

  • 1

Range:

  • 0: No Change
  • 1: Restore Thermostat Factory Settings (minus z-wave)
  • Default: 0

Temperature Calibration

Parameter Number:

  • 5

Size (bytes):

  • 1

Range:

  • 0-5: 0 – 5°F 0 – 2.8°C
  • 251-255: (-5)-(-1)°F (-1) – (-2.8)°C
  • Default: 0

LED Dimming (If applicable)

Parameter Number:

  • 6

Size (bytes):

  • 1

Range:

  • 0: Low
  • 1: Medium
  • 2: High
  • 3: Auto
  • Default: 3

Demand Response Mode

Parameter Number:

  • 7

Size (bytes):

  • 1

Range:

  • 0: Off
  • 1: On
  • Default: 0

Swing Setting

Parameter Number:

  • 8

Size (bytes):

  • 1

Range:

  • 0-10: 0 – 10°F 0 – 5.6°C
  • *Note: In case user attempts to set swing larger than differential, the differential will be set
    equal to the new swing value.
  • Default: 1

Differential Setting

Parameter Number:

Size (bytes):

  • 1

Range:

  • 0-10: 0 – 10°F 0 – 5.6°C
  • Default: 3

OTA (Over The Air) programming error code

Parameter Number:

  • 10

Size (bytes):

  • 1

Range:

  • 0: No error
  • 1: Battery low, reflashing not possible
  • 2: OTA cancelled before completion
  • 3: Fragment CRC error
  • 4: Total image CRC error
  • 5: External flash error
  • 6: Fragment received out of order
  • 7: Invalid firmware or manufacture ID
  • 8: OTA session not properly initialized
  • 9: Same image currently running
  • 10: Time out during OTA download between fragments
  • Default: 0

Association Group

This thermostat supports a single Z-Wave Association Group (Group 1) called the “lifeline.” All thermostat related commands are sent to the NodeID programmed in Group 1. Z-Wave commands that are sent to Group 1 include:

  • Battery Level
  • Thermostat heat set point
  • Thermostat cool set point
  • Device local reset notification
  • Temperature
  • Humidity
  • Fan mode
  • Fan mode current state of operation
  • Thermostat mode
  • Thermostat current state of operation

Let's create a cleaner energy future... together